1,281 research outputs found

    Impact of the motor magnetic model on direct flux vector control of interior PM motors

    Get PDF
    The stator-field-oriented, direct-flux vector control has been proven to be effective in terms of linear torque control and model independent performance at limited voltage and current (i.e. in flux weakening) for AC drives of various types. The performance of the direct-flux vector control relies on the accuracy of the flux estimation, as for any field oriented control. The knowledge of the motor magnetic model is critical for flux estimation when the operating at low speed. This paper addresses the effects of a limited knowledge of the motor model on the performance of the control at low speed, for an Interior Permanent Magnet motor drive. Experimental results are give

    Unified Direct-Flux Vector Control for AC Motor Drives

    Get PDF
    The paper introduces a Unified Direct-Flux Vector Control scheme suitable for sinusoidal AC motor drives. The AC drives considered here are Induction Motor, Synchronous Reluctance and synchronous Permanent Magnet motor drives, including Interior and Surface-mounted Permanent Magnet types. The proposed controller operates in stator flux coordinates: the stator flux amplitude is directly controlled by the direct voltage component, while the torque is controlled by regulating the quadrature current component. The unified direct-flux control is particularly convenient when flux-weakening is required, since it easily guarantees maximum torque production under current and voltage limitations. The hardware for control is standard and the control firmware is the same for all the motors under test with the only exception of the magnetic model used for flux estimation at low speed. Experimental results on four different drives are provided, showing the validity of the proposed unified control approac

    Multipolar SPM machines for direct drive application: a comprehensive design approach

    Get PDF
    A closed-form, per-unit formulation is proposed, for the design of surface mounted permanent magnet motors with high number of poles. The model evaluates the shear stress, the power factor and the specific Joule loss as the indicators of the machine performance, and demonstrates that this is determined by the correct choice of a very limited set of key-geometrical parameters. The design criteria are described analytically and then applied to example designs, FEA validated. Distributed- and concentrated-winding configurations are considered. The conclusions of the paper are consistent with the literature and aim to give a roadmap for designers of PM machines in modern applications, such as wind power synchronous generator

    An Integral Battery Charger with Power Factor Correction for Electric Scooter

    Get PDF
    This paper presents an integral battery charger for an electric scooter with high voltage batteries and interior-permanent-magnet motor traction drive. The battery charger is derived from the power hardware of the scooter, with the ac motor drive that operates as three-phase boost rectifier with power factor correction capability. The control of the charger is also integrated into the scooter control firmware that is implemented on a fixed-point DSP controller. Current-controlled or voltage-controlled charge modes are actuated according to the requirements of the battery management system, that is embedded into the battery pack. With respect to previous integrated chargers, the ac current is absorbed at unitary power factor with no harmonic distortion. Moreover, no additional filtering is needed since the pulsewidth modulation ripple is minimized by means of phase interleaving. The feasibility of the integral charger with different ac motors (induction motor, surface-mounted phase modulation motor) is also discussed, by means of a general model purposely developed for three-phase ac machines. The effectiveness of the proposed battery charger is experimentally demonstrated on a prototype electric scooter, equipped with two Li-ion battery packs rated 260 V, 20 A

    Direct Flux Field Oriented Control of IPM Drives with Variable DC-Link in the Field-Weakening Region

    Get PDF
    This paper presents the direct flux control of an interior permanent-magnet (IPM) motor drive in the field-weakening region. The output torque is regulated by the coordinated control of the stator flux amplitude and the current component in quadrature with the flux, and it is implemented in the stator flux reference frame. The control system guarantees maximum torque production taking into account voltage and current limits, in particular in case of large dc-link variations. The field-oriented control does not necessarily require an accurate magnetic model of the IPM motor, and it is able to exploit the full inverter voltage at different dc-link levels with no additional voltage control loop. The feasibility of the proposed control method is investigated in discrete-time simulation, then tested on a laboratory rig, and finally implemented on board of an electric scooter prototype. The motor under test is an IPM permanent-magnet-assisted synchronous reluctance machine, with high-saliency and limited permanent-magnet flu

    Core Losses and Torque Ripple in IPM Machines: Dedicated Modeling and Design Trade Off

    Get PDF
    The proper combination of stator and rotor slot numbers is pursued in the design of interior permanent-magnet (IPM) motors with wide constant-power speed range. At high speed, in the flux-weakening region, the arising of stator and rotor iron losses due to magnetomotive-force (MMF) spatial harmonics limits the IPM motor performance. Torque ripple is another problem for this kind of machines, both at low and high speed. The numbers of stator slots and rotor equivalent slots have a major impact on both the loss and ripple aspects. A simplified model is proposed here in order to evaluate both problems with a general approach and point out the possible design tradeoff. With respect to previous models in the literature, both stator and rotor losses are included, and a more comprehensive approach is followed in the description of the rotor MMF harmonics. The model's effectiveness is tested through finite element analysis simulations and some experimental results. The proposed approach is useful for the selection of the IPM machine structure according to the specific requirements of the applicatio

    Position estimation delays in signal injection-based sensorless PMSM drives

    Get PDF
    The causes of position estimation delays and their effects on the sensorless control of permanent magnet synchronous motor drives are investigated. The position of a permanent magnet synchronous machine is estimated via the injection of high frequency voltage signals. The delays under investigation are due to the digital implementation of the control algorithm and to the digital filters adopted for decoupling the inspection signals from the fundamental components of the stator current measures. If not correctly modeled and compensated, such delays can reduce the performance of the control scheme. Experimental results are provided, proving the accuracy of the modeling approach and the effectiveness of the related compensation strateg
    corecore